Solution to the failure of pulse dust collector
2019-04-26
Technical theme | Cause | Solution |
1. The powder content of the air outlet is too high |
1. The filter cloth bag is damaged 2. The bandage of the filter cloth bag falls off or becomes loose |
1. Replace the damaged filter cloth bag 2. Re-tie the filter cloth bag |
2. The dust resistance increases and continues to rise |
1. Insufficient air pressure for blowback 2. Air leakage in the pipeline reduces the pressure 3. The solenoid valve does not work properly |
1. Adjust the output pressure of the air compressor 2. Repair the air duct 3. Overhaul or replace the solenoid valve |
3. The pressure of the gas storage bag is low |
1. The air compressor fails 2. Leakage of pipeline and gas storage bag 3. The solenoid valve diaphragm is damaged 4. The solenoid valve is not closed tightly 5. The pulse period is too short |
1. Repair the air compressor 2. Repair the pipeline and gas storage bag 3. Replace the solenoid valve diaphragm 4. Repair or replace the solenoid valve 5. Adjust the pulse period |