Service Hotline:400-116-0066

>
>
>
A solution to the Fault of Pulsed Precipitato

CASES

 

CASES

A solution to the Fault of Pulsed Precipitato

Classification:
FAQ
Author:
Source:
2019/04/26 10:31
Page view
Review:
[Abstract]:
The dust content in the outlet air is too high, the dust resistance increases and continues to rise, and the pressure of the air storage bag is low.
Technical theme Cause Rx
1. The air in the outlet is too high in powder content.

1, filter bag damage

2, cloth bag binding shedding or loosening

1, replace the damaged filter bag

2, rebind filter bag

2. Dust resistance increases and continues to rise

1, backblown air pressure is insufficient

2. Pipe leakage reduces pressure

3, solenoid valve action failure

1, adjust the output pressure of the air compresso

2, maintenance of air piping

3, repair or replace solenoid valve

3, low pressure of air storage package

1. Air compressor failure

2, pipeline and gas storage vents leak

3, electromagnetic valve diaphragm breakage

4, solenoid valve closure is not strict

5. The pulse period is too short.

1, maintenance of air compresso

3, replace solenoid diaphragm

3, replace solenoid diaphragm

4, repair or replace solenoid valve

5, adjust pulse period

 